Home  >  Beauty Equipment  >  Laser Beauty Equipment

ER:BIUM Fractional laser 1550nm Face lifting Medical CE Approved - YILIYA-1550A

Fractional ER:BIUM Glass laser 1550nm.Max 35Walt IPG laser power.Anti-age,wrinkles remove, Acne scars removal,no downtime - more info check here: https://www.sourcingbeauty.com/ER-BIUM-Fractional-laser-1550nm-Face-lifting-Medical-CE-Approved-11023027/

Quick Brief

Type: Laser Laser Type: Er:bium Glass fractional laser Q-Switch: No Style: Stationary Certification: Medical CE Place of Origin: Beijing China (Mainland) Brand Name: YILIYA Model Number: YILIYA-1550A laser source: Imported from IPG Germany laser power: 30Walt,THE BEST IN THE WORLD TUV Approved: Medical CE Energy: 200mj MAX Scanning Paterns: 5 paterns Output way: Fiber laser Safe for all skin type: no downtime

Product Features:

Fractional ER:BIUM Glass laser 1550nm.Max 35Walt IPG laser power.Anti-age,wrinkles remove, Acne scars removal,no downtime

Business Terms:

Port: Guangzhou,Tianjin

Minimum Order Quantity: 1 Set/Sets

Supply Ability: 50 Set/Sets per Month

Payment Terms: T/T

Contact Supplier
ER:BIUM Fractional laser 1550nm Face lifting Medical CE Approved
Share to: Facebook Twitter LinkedIn Google+

Product Packagings & Delivery Terms:

Packaging Detail: Aluminum Package

Delivery Detail: 7-10 working days after payment

Specifications and Product Details:

Non ablative Skin reconstruction,Face lifting,Neck lifting.anti-age,acne scars removal machine.

Carol.*_* 86 134 010 67552

Treatment Theroy

The Er:bium Glass fractional laser skin reconstruction system adopts fiber laser with 1550nm wavelength and installs a CPG which is arranged in matrix scanning output, emitting 50um-80um spot through a high focusing lens, the target tissue is water in the dermis, forming matrix-like hole (0.12mm) around focal spot penetration directly. The penetration depth of these small spots is about 2mm (the depth is related with solar elastic fibrotic maximum depth). At this point the normal tissue among holes generates heat bridge which starts wound rehabilitation reaction and thermal effects between scarfskin and dermal tissue, then experiencing inflammation phase, proliferation phase, remodeling phase. Drugs or cosmetic essence can be applied into the wound rehabilitation reaction, 1 hour after laser irradiation, the dermal fibrous tissue arranged dense, few inflammatory cells soakage, after 3 days proliferation of epidermal cells, inflammatory cells of dermal layer and fibroblast cells are increased. 7days fibroblasts in dermal layer is increased significantly, 15 days increasing in collagen synthesis, dermal thickening. After laser irradiation there is a certain effect for skin elasticity, skin hemoglobin content, water loss through the skin, sebum content, skin moisture content but no impact on the skin melanin content
Application
1. Patients with mild to moderate photoaging: Rough skin, large pores, fine wrinkles, skin loosen.

2. Wrinkles caused by sunlight or early aging wrinkles, on the lower eyelid, forehead, cheek as well as crow's-feet.

3. Face lifting and tightening. Neck skin lifting wrinkle removal.

4. Acne scar Removal.Acne Removal.Atrophic Scars Removal

1550A
1. The target tissue is water, no skin color limit, Fitzpatrick I-VI are within application;

2. The output spot diameter is 50-80 um, less thermal ablation and deeper penetration.

3. Random scanning avoids thermal damage caused by heat accumulation, reducing pain of treatment;

4. Applied1550nm fiber laser from IPG, the maximum output power is 35W which is 2-3 times of similar equipment, ensuring a deep penetration and long lifetime.BEST LASTER IN THE FULL MARKET.

5. 6 scan patterns (Circle / Triangle/ Square/ Rectangle / Rhombus ) are available via CPG for different parts of skin, satisfying different therapists unique request;

6. Laser output spot size, energy density, scan pattern, scanning speed, spot density, scanning area are adjustable , which were controlled by the computer operating system for various lesions, the tissue can be gasified at different depths (50-2000um), to ensure a more accurate treatment;

7. Honkon also supply Er:bium Glass laser with maximum output power 15W and 25W to satisfy different purchasing requests.

Technical Parameters:

Power SupplyAC 220V 50Hz / AC 110V 60Hz
Beam DeliveryFiber
Wavelength1550nm
Optical Beam QualityTEM00
Maximum Output Power30W/20W/10W
Spot Diameter0.05-0.08mm
Spot PatternCircle / Triangle/ Square/ Rectangle / Rhombus /Line
Scan Area Spot Volume

(Square)

16 spots4×436 spots6×664 spots8×8

100 spots10×10144 spots12×12

Spot Density×1 / ×2 / ×3 / ×4 / ×5 / ×6
Aiming Beam Wavelength635 nm
Aiming Beam Power≤5mW
Scanning ModeRandom Scanning
Pulse Energy10mj~200mj (every stepping: 2mj)
Pulse Interval1ms~100ms (every stepping: 1ms)
Working ModeContinuous operation with intermittent loading
CoolingAir Cooling
Dimensions (before packaged)650mm*340mm*760mm
Dimensions (After Packaged)900mm*470mm*1000mm
Net Weight33KGS
Gross Weight76KGS
ER:BIUM Fractional laser 1550nm Face lifting Medical CE Approved suppliers    ER:BIUM Fractional laser 1550nm Face lifting Medical CE Approved manufacturers